In the list of configured drivers delete any drivers you created in previous attempts.Select Cofigure Drivers from the Communications menu.Click on Communications from the menubar.Close the RSWho window that opens automatically on startup.Here is a step by step on adding the driver: In fact, if there were security it should tell you that you are not authorized to make those changes. You are right, if you can add one driver then you should be able to add any others as well. I doubt this though, because can add DH+ drivers with a PCMK card, so it would seem to me if I can and those, I should be able to add anything.ĥ. Another guy set up the others, I'm wondering now if it's possible that he locked this function out as an administrator or something. Thanks for the input, keep it coming, cause I'm still stumped. When I select the Remote device, and name it, and then it jumps to hostname, I put the number in, click ok, and the screen jumps back to the original configure screen, and the driver is not added. It will not allow me to set up a new driver for it either way. Thanks again for the help, but it is still not working. If you have two ControlLogix ethernet modules, you would have to enter a whole new driver for the second module.Īlso, if you are not familiar with shortcuts, you might look into setting up an RSLinx shortcut to your DHRIO (assuming you have one of those since you are going to a PLC5).Ĥ. The driver you have chosen will only talk to one device. This driver would allow you to enter in the IP address of all your ethernet devices (up to 255 devices) on a single driver. On another note, a better driver to choose would be the Ethernet devices driver. Click on the driver name (TCP-1 is the default) on the left and see if you can drill down through your ethernet module to the backplane. Go to the RSWho window by clicking on Communications and RSWho. Your driver should now be listed in the Configured Drivers section. The Server Name and Remote Driver Name field will be blank. It is browsing for an RSLinx Gateway.Īdd your driver exactly as you were indicating by typing in the IP address in the "Server's IP address or hostname" field. This is why the browse does not appear to do anything. You are going through a COntrolLogix to a remote device. The driver you have chosen is not really the best one for talking to your ControlLogix (or your PLC5 thru the CLogix)however, it certainly can work.įirst off, the driver you are using is intended for a computer to go through a RSLinx Gateway to a remote device. I would like to do this laptop the same as the others.ģ. When I click configure on a laptop which already has it, it shows it as a remote device, and under the server IP address, it shows the number I have typed above. When I look at the other laptops to see how they are set up, they are called, Build49 to on 165.152.60.95. What I am trying to do is talk to a 5 thru a ControlLogix5000. THanks for the post Ken, but I still haven't gotten it.
![how to configure drivers in rslinx classic how to configure drivers in rslinx classic](https://uploads-ssl.webflow.com/5e4c4a3ffa444d333b501251/5e56db3b275d7c21e8a74139_rslinxnetworksplc2.jpeg)
Type in the IP addresses of the PLCs you want to talk to, click Apply, and you should be able to browse the AB_ETH driver.Ģ.
![how to configure drivers in rslinx classic how to configure drivers in rslinx classic](https://www.clicksconcepts.com/wp-content/uploads/2016/04/RSLinx-Ethernet-Driver-configuring.png)
You'll find a table of "Station = Host Name" assignements. Choose the "AB_ETH-1" driver and click on Configure. To communicate with Ethernet-equipped PLCs, select Communications -> Configure Drivers.
![how to configure drivers in rslinx classic how to configure drivers in rslinx classic](https://www.dmcinfo.com/Portals/0/rslinx_config_DF1.gif)
#How to configure drivers in rslinx classic software
You shouldn't have to use the "Remote Devices via Linx Gateway" unless you're genuinely connecting to an installation of RSLinx Gateway software somewhere else on your TCP/IP network. Can anyone give me a step by step or see what I am missing? Thanks in advance.ġ. If I click browse after putting the number in there, the apply tag lights up, but when I click on it, nothing happens, and nothing is added. Under the server IP address or hostname, I am putting in the number that it shows on the other laptops. This brings up the configure remote devices box. I have gone in and selected remote devices via Linx gateway. I am trying to add another ethernet driver to the list of configured drivers on RSLinx Lite. Home Conferences *** LIVE PLC Q&A *** (Public) New Here? Please read this important info!!! Your Personal PLC Tutor Site - Interactive Q & A Please DON'T use it for advertising, etc. Your Personal PLC Tutor Site - Interactive Q & A - "Adding Ethernet driver to RSLinx"